CUSTOMER:
Expansion Valve Division of a Major Manufacturer
PROBLEM:
Provide a 180-stop rotary indexing system. The base indexes every five (5) seconds and utilizes an eight (8) foot diameter aluminum dial plate.
SOLUTION:
Provide a 180-stop rotary indexing system. The base indexes every five (5) seconds and utilizes an eight (8) foot diameter aluminum dial plate.
SPECIAL CONSIDERATIONS:
The transporting device had to be able to hold 150 to 180 pieces at a time.
Design of the indexer must allow the automatic loading of the parts.
The carriage of the machine could not be influenced by the heat of the oven.
EQUIPMENT FURNISHED:
Eight (8) feet diameter rotary index system complete with adjustable speed controls.
180 parts fixtures with capability of withstanding high temperatures